TransPAC Network Operations Report
06/26/2017 - 07/02/2017

TransPAC Network Operations Center
at Indiana University

New Connections

None


Upgrades

None


New Services

None


Unscheduled Outages Summary

Ticket Number Customer Impact Network Impact Title Outage Type Source Of Impact Start Time (UTC) End Time (UTC)

18562-High 2-High Outage Resolved- TransPAC Backbone SEAT-TOKY Circuit - Damaged FiberVendor 06/27/2017 3:03 PM 06/27/2017 7:39 PM

Unscheduled Outages Detail


Ticket No.:1856:62
Subject:Outage Resolved- TransPAC Backbone SEAT-TOKY
Source Of Impact:Vendor
Affected:TransPAC Backbone SEAT-TOKY
TransPAC Peer APAN
Start Time:Tuesday, June 27, 2017, 3:03 PM (1503) UTC
End Time:Tuesday, June 27, 2017, 7:39 PM (1939) UTC
Description:The TransPAC SEAT-TOKY Backbone Circuit is now available. The circuit provider stated that the outage was caused due to a terrestrial cable fault. Services have restored upon completion of the cable repair. No further outages are expected.

Scheduled Maintenances Summary

Ticket Number Customer Impact Network Impact Title Maintenance Type Source Of Impact Start Time (UTC) End Time (UTC)

None during this report period

Downtime and Availability



TransPAC Core NodesDown TimeReporting Period Availability52 Week Availability
TransPAC MX480 - LA0 hr 0 min100.00000%100.00000%
Brocade MLXe40 hr 0 min100.00000%100.00000%
3410 Ethernet Switch0 hr 0 min100.00000%100.00000%
OOB Router0 hr 0 min100.00000%100.00000%

Aggregate TransPAC Core Nodes0 hr 0 min100.00000%100.00000%

TransPAC Backbone CircuitsDown TimeReporting Period Availability52 Week Availability
TP-LOSA-TOKY-10GE-10 hr 0 min100.00000%100.00000%
TP2-LOSA-LOSA-100GE-015210 hr 0 min100.00000%100.00000%
TP2-LOSA-LOSA-10GE-015200 hr 0 min100.00000%100.00000%
TP2-SEAT-TP-SEAT-TP-100GE-015230 hr 0 min100.00000%100.00000%
TP2-SEAT-TP-TOKY-100GE-015224 hr 36 min97.26190%99.05168%

Aggregate All TransPAC Backbone Circuits4 hr 36 min99.45238%99.81034%




Upcoming Scheduled Maintenances